Rotaria
Datasheet
Rotaria KWA floating decanter

Floating decanter for SBR plants

Decants clear water from below the surface with no drive in the tank. All stainless steel 316Ti, designed to DWA‑M 210. Two weighted flaps open passively during decanting and stay sealed during aeration and mixing.

Rotaria KWA in an SBR tank: oval stainless steel float with decanting chamber, rigid stainless steel outlet pipe with swivel joint to the tank wall, a mixer alongside.

Design

Typefloating decanter with decanting chamber and two weighted closing flaps
Drive in/on the tanknone
Controlmotorised valve in the outlet chamber or decant pump
Design basisGerman DWA-M 210 guideline for SBR plants
Frost protectiondown to -20 °C (support structure below the bottom water level)
Outlet piperigid stainless steel pipe with swivel bearings at the tank wall
Fault protectionfloor stand limits the lowest position
Commissioningfilled and vented via ball valves while the tank is filled
Float, decanting chamber, outlet pipe, supportsstainless steel 1.4571 / AISI 316Ti (alternatively 1.4404 / 316L)
SealsEPDM
Floatwelded stainless steel

Sizes

We build the Rotaria KWA for decant rates from 90 to 800 m³/h and size it precisely to your tank.

Supplied so far: 90, 100, 105 and 387 m³/h, DN 100 to DN 300, tank depth 5 to 6 m, water level variation approx. 1.5 to 1.9 m.

Dimensions, example 387 m³/h

Float (L × H)2,600 × 400 mm
Decanting chamber, length1,512 mm
Inlet slot (L × H)1,300 × 160 mm
Top of inlet slot158 mm below underside of float
Overall height of decanter head1,111 mm
OutletØ 323.9 mm (DN 300)
Dimension drawing of the 387 m³/h decanter head: float 2600 mm long and 400 mm high, decanting chamber 1512 mm with inlet slot 1300 by 160 mm, outlet diameter 323.9 mm, overall height 1111 mm.
Decanter head 387 m³/h, dimensions in mm

Suitable for

  • Municipal and industrial SBR plants
  • Retrofitting existing SBR tanks
  • Tanks from about 4 m deep
  • Water level variation up to approx. 1.9 m
  • Decant rates from 90 to 800 m³/h
  • Outdoor installation down to -20 °C

Not suitable or to be checked

  • Tanks without a motorised valve or decant pump for control
  • Water level variation above approx. 1.9 m
  • Very shallow tanks under about 4 m
  • Decant rates above 800 m³/h
  • Tanks with a very thick scum layer

Options

Tender specification and sizing: products.rotaria.com/en/sbr-decanter/ · info@rotaria.com